Topology rules
Topology rules for RT
● A topology can be, but need not be configured for RT. If a topology has been configured,
● Otherwise, the wiring between devices is entirely optional.
Topology rules for IRT
● Mixed operation is not supported by STEP 7 V5.4 SP4, i.e. IRT "high performance"
● A synchronization domain with IRT "high performance" can contain a maximum of one
● IRT "high flexibility" is subject to the same topology rules as IRT "high performance", the
Device selection in HW Config
Hardware catalog:
The drive unit from the appropriate unit family entry in the hardware catalog must be
configured. For the RT class IRT, these are all entries with the end identification ...PN-V2.2.
GSD:
The names of GSD files for devices which contain IRT end in ...PN-V2.2.
10.3.4

PROFINET GSDML

To embed a SINAMICS S into a PROFINET network, SINAMICS S120 supports two different
PROFINET GSDML versions (generic station description file):
● PROFINET GSDML for compact modules
● PROFINET GSDML with subslot configuring
PROFINET GSDML for compact modules
With PROFINET GSDML, you can precisely configure a complete module, which
corresponds to a drive object (Drive Object=DO). Each of these modules involves two
subslots: The Parameter Access Point (PAP) and a PZD telegram for transferring process
data. You can identify the PROFINET GSDML for compact modules by the following
structure of the file name:
GSDML-V2.2-Siemens-Sinamics_S_CU3x0-20090101.xml (example)
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
the devices must be wired in accordance with the topology.
cannot be combined with IRT "high flexibility" in the same synchronization domain.
IRT "high performance" island. "Island" means that the devices must be interconnected to
match the configured topology. A synchronization master must be positioned in the
relevant island.
only exception being that a topology does not need to be configured. However, if a
topology has been configured, the devices must be wired to match the topology.
10.3 Communication via PROFINET IO
Communication
643