Function modules
7.2 Extended monitoring functions
Figure 7-3
Commissioning
The extended monitoring functions are activated while the commissioning wizard is running.
Parameter r0108.17 indicates whether it has been activated.
Function diagrams (see SINAMICS S120/S150 List Manual)
● 8010 Speed messages 1
● 8011 Speed messages 2
● 8013 Load monitoring
Overview of important parameters (see SINAMICS S120/S150 List Manual)
Load monitoring
● p2181[D] Load monitoring response
● p2182[D] Load monitoring speed threshold 1
● p2183[D] Load monitoring speed threshold 2
● p2184[D] Load monitoring speed threshold 3
● p2185[D] Load torque monitoring torque threshold 1 upper
● ...
● p2190[D] Load torque monitoring torque threshold 3 lower
● p2192[D] Load monitoring delay time
322
Load monitoring
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2