● p0607[0...n] temperature sensor fault timer stage
● p0608[0...3] CI: Motor temperature, signal source 2
● p0609[0...3] CI: Motor temperature, signal source 3
● p0610[0...n] motor overtemperature reaction
● p0624[0...n] motor temperature offset PT100
● p0625[0...n] motor ambient temperature
● p4600[0...n] motor temperature sensor 1 sensor type
● p4601[0...n] motor temperature sensor 2 sensor type
● p4602[0...n] motor temperature sensor 3 sensor type
● p4603[0...n] motor temperature sensor 4 sensor type
● r4620[0...3] measured motor temperature
Additional parameters for TM31
● p4100 TM31 temperature evaluation sensor type
● p4102[0...1] TM31 temperature evaluation, fault/alarm threshold
● p4103 TM31 temperature evaluation timer
● r4104.0...1 BO: TM31 temperature evaluation status
● r4105 CO: TM31 temperature evaluation actual value
Additional parameters for TM120
● p4100[0...3] TM120 temperature evaluation sensor type
● r4101[0...3] TM120 temperature evaluation, sensor resistance
● p4102[0...7] TM120 temperature evaluation, fault/alarm threshold
● p4103[0...3] TM120 temperature evaluation, timer
● r4104.0...7 BO: TM120 temperature evaluation status
● r4105 [0...3] CO: TM120 temperature evaluation actual value
Additional parameters for TM150
● p4100[0...11] TM150 temperature evaluation sensor type
● r4101[0...11] TM150 temperature evaluation sensor resistance
● p4102[0...23] TM150 temperature evaluation, fault/alarm threshold
● p4103[0...11] TM150 temperature evaluation, timer
● r4104.0...23 BO: TM150 temperature evaluation status
● r4105[0...11] CO: TM150 temperature evaluation actual value
● p4108[0...5] TM150 measurement method
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Monitoring and protective functions
8.5 Thermal motor protection