Inputs/Outputs - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

12.5

Inputs/outputs

The following digital/analog inputs/outputs are available:
Table 12- 6
Overview of inputs/outputs
Component
CU320-2
CU310-2
TB30
TM15DI_DO
TM31
TM41
TM120
1) Variable: non-isolated or isolated
2) of which, 6 "rapid inputs"
3) additional inputs for Safety Integrated Basic Functions
Note
For detailed information about the hardware properties of I/Os, please refer to
document: SINAMICS S120 Equipment Manual Control Units.
For detailed information about the structural relationships between all I/Os of a component
and their parameters, please refer to the function diagrams in
document: SINAMICS S120/S150 List Manual.
12.5.1
Digital inputs/outputs
Signal processing using the digital inputs is shown in the function diagrams listed below.
Properties
● The digital inputs are "high active".
● An open input is interpreted as "low".
● Fixed debounce setting
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Inputs
12
1)
5+3
3)
4
-
8
Relay outputs: 2
Temperature sensor input: 1
4
Incremental encoder emulation: 1
Temperature sensor inputs: 4
Delay time = 1 to 2 current controller cycles (p0115[0])
Digital
Bidirectional
Outputs
inputs/outputs
8
2)
8+1
3)
-
24
4
4
Basic information about the drive system
Analog
Inputs
-
-
-
1
4
2
-
-
-
2
-
1
12.5 Inputs/outputs
Outputs
-
-
2
-
2
-
719