Basic information about the drive system
12.12 System sampling times and number of controllable drives
5. For Active Line Modules (ALM) in chassis format, only a current controller sampling time
6. For Basic Line Modules (BLM), only a current controller sampling time of 2000 µs can be
7. For Motor Modules in chassis format, a current controller sampling time of minimum 125
8. For Motor Modules in blocksize format, a current controller sampling time of 62.5 µs,
9. When a chassis unit is connected to a DRIVE-CLiQ line, the smallest current controller
10. A current controller sampling time between 31.25 µs and 250.0 µs can be set for servo
11. A current controller sampling time between 125.0 µs and 500.0 µs can be set for servo
12. For servo drives with a current controller sampling time of p0115[0] = 62.5 µs, the
13. Isochronous PROFIBUS operation (set p0092 = 1):
14. For vector and vector U/f control modes, and when using a sine-wave filter (p0230 > 0), it
770
of 250.0 µs or 400.0 µs / 375.0 µs (375 µs when p0092 = 1) can be set.
set.
µs can be set (125 µs ≤ p0115[0] ≤ 500 µs). This applies to the Servo and Vector control
types.
125.0 µs, 250.0 µs, or 500.0 µs can be set (only pulse frequencies in multiples of 2 kHz
permitted).
sampling time must be at least 125 µs. This applies only to the Servo control type.
Example:
Mixture of chassis and booksize units on a DRIVE-CLiQ line.
drives (31.25 µs ≤ p0115[0] ≤ 250.0 µs).
drives (125.0 µs ≤ p0115[0] ≤ 500.0 µs).
following applies:
– Only possible in booksize and blocksize format.
Maximum number of components/devices:
– Booksize: 2 servo with p0115[0] = 62.5 µs + Line Module (connected to a different
DRIVE-CLiQ line)
– Blocksize: 1 servo with p0115[0] = 62.5 µs
– Booksize servo drives can be combined on one DRIVE-CLiQ line with a servo with
p0115[0] = 125.0 µs (but with same quantity framework).
– The current controller sampling time must be a multiple of 125.0 µs, 62.5 µs or
31.25μs.
is only permissible to change the current controller sampling time of the DO involved in
multiple integer steps of the default value.
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2