Tel. word = telegram word
Note
For double words, 2 PZD must be read in succession. Read a 32-bit setpoint that is at PZD
2+PZD 3 of the telegram from node 2, and map this to PZD 2+PZD 3 of node 1:
p8872[1] = 2, p8870[1] = 2, p8872[2] = 2, p8870[2] = 3
Activation
To activate SINAMICS Link connections, perform a POWER ON for all nodes. The
assignments of p2051[x]/2061[2x] and the links of the read parameters r2050[x]/2060[2x]
can be changed without a POWER ON.
10.4.4

Example

Task
Configure SINAMICS Link for three nodes for isochronous data transfer. Each of the nodes
of this example consists of a drive train with a CU320-2PN, a CBE20 and a servo drive.
Each node sends a telegram and takes PZDs (process data words) from the telegrams
available on the SINAMICS Link. The torque actual value from drive object 2 should be
interconnected as torque setpoint for drive object 3. The following values are to be
transferred:
Figure 10-63 SINAMICS Link configuration example
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
10.4 Communication via SINAMICS Link
Communication
673