Bit
Meaning
3
Reserved
4
Reserved
5
Alarm class bit 0
6
Alarm class bit 1
7
Reserved
8
Reserved
9
Limit speed setpoint
10
Upper torque limit
11
Lower torque limit
12
Reserved
13
Safe Stop 1
14
Safe Torque Off active
(safe stop)
15
Controller sign of life
toggle bit
ZSW2_ENC (status word 2 encoder)
See function diagram [2434].
Table 10- 28 Description of ZSW2_ENC (status word 2 encoder)
Bit
Meaning
0...2
Reserved
3
Fault active
4...6
Reserved
7
Alarm active
8
Reserved
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
-
-
-
-
Bits 5-6: Alarm stage of SINAMICS drives,
transferred as attribute in alarm message
value = 0: Alarm (previous alarm stage)
value = 1: Alarm class A
value = 2: Alarm class B
value = 3: Alarm class C
-
-
-
-
1
Speed setpoint limited
0
Speed setpoint not limited
1
Upper torque limit reached
0
Upper torque limit not reached
1
Lower torque limit reached
0
Lower torque limit not reached
-
-
1
Normalized signal according to PROFIdrive on
PROFIsafe
1
Normalized signal according to PROFIdrive on
PROFIsafe
1
Toggle bit communication active
0
Toggle bit communication not active
1
Fault active
The drive is faulty and, therefore, out of service.
The drive switches to "switching on inhibited" once
the fault has been acknowledged and the cause
has been remedied.
The active faults are stored in the fault buffer.
0
No fault active
No active fault in the fault buffer.
1
Alarm active
0
No alarm active
10.1 Communication according to PROFIdrive
Remarks
Remarks
Communication
Parameter
-
-
BO: r2139.11
BO: r2139.12
-
-
r1407.11
r1407.8
r1407.9
-
r9773.2
r9773.1
r2093.15
Parameter
BO: r2139.3
r2139.7
541