4.13

Current controller adaptation

Description
Current controller adaptation can be used to adapt the P gain of the current controller and
the dynamic pre-control of the Iq current controller depending on the current. The current
controller adaptation is directly activated with setting p1402.2 = 1 or deactivated with
p1402.2 = 0. It is automatically activated with p1959.5 (p1959.5 = 1) or deactivated (p1959.5
= 0).
Figure 4-18
or (e.g for the ASM) when the iq points are swapped
Figure 4-19
Function diagrams (see SINAMICS S120/S150 List Manual)
● 6710 Current setpoint filters
● 6714 Iq and Id controller
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p0391 Current controller adaptation starting point KP
● p0392 Current controller adaptation starting point KP adapted
● p0393 Current controller adaptation P gain scaling
● p1402[0...n] Closed-loop current control and motor model configuration
● p1703 Isq current controller pre-control scaling
● p1715 Current controller P gain
● p1717 Current controller integral time
● p1959[0...n] Rotating measurement configuration
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Current controller adaptation for p0393 < 1, with p0391 < p0392
Kp
p1715 x p0393
p1715
p0392
Current controller adaptation with swapped iq interpolation points for p0393 > 1, with
p0392 < p0391
4.13 Current controller adaptation
p0391
Iq
Vector control
173