Determined data (gamma)
r1936 magnetizing inductance identified
r1973 encoder pulse number identified
Note:
The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408) and is only suitable for
making rough checks. The sign is negative if inversion is required (p0410.0).
-
Note:
If the encoder inversion is changed using motor data identification, fault F07993 is output, which refers to a possible
change in the direction of rotation and can only be acknowledged by p1910 = -2.
Table 3- 13
Data determined using p1960 for induction motors (rotating measurement)
Determined data (gamma)
r1934 q Inductance identified
r1935 q Inductance identification current
Note:
The q inductance characteristic can be used as basis to manually determine the data for the current controller adaptation
(p0391, p0392 and p0393).
r1936 magnetizing inductance identified
r1948 magnetizing current identified
r1962 saturation characteristic magnetizing current
identified
r1963 saturation characteristic stator inductance
identified
Note:
The magnetic design of the motor can be identified from the saturation characteristic.
r1969 moment of inertia identified
r1973 encoder pulse number identified
Note:
The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408) and is only suitable for
making rough checks. The sign is negative if inversion is required (p0410.0).
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Data that are accepted (p1910 = 1)
r0382 motor main inductance, transformed (gamma)
p0360 motor main inductance
p1590 flux controller P gain
p1592 flux controller integral action time
-
p0410 encoder inversion actual value
Data that are accepted (p1960 = 1)
-
r0382 motor main inductance, transformed (gamma)
p0360 motor main inductance
p1590 flux controller P gain
p1592 flux controller integral action time
p0320 rated motor magnetizing current
-
-
p0341 Motor moment of inertia
* p0342 Ratio between the total moment of inertia and that of the
motor
+ p1498 Load moment of inertia
-