Extended setpoint channel

2.6 Main/supplementary setpoint and setpoint modification

Parameterization with STARTER
The "speed setpoint jog" parameter screen is selected via the following symbol in the toolbar
of the STARTER commissioning tool:
Figure 2-5
2.6
Main/supplementary setpoint and setpoint modification
Description
The supplementary setpoint can be used to incorporate correction values from lower-level
controllers. This can be easily carried out using the addition point for the
main/supplementary setpoint in the setpoint channel. Both variables are imported
simultaneously via two separate or one setpoint source and added in the setpoint channel.
Figure 2-6
Function diagrams (see SINAMICS S120/S150 List Manual)
● 1550 Setpoint channel
● 3030 Main/supplementary setpoint, setpoint scaling, jog
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p1070[C] CI: Main setpoint
● p1071[C] CI: Main setpoint scaling