Siemens Sinamics S120 Function Manual page 560

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Communication
10.1 Communication according to PROFIdrive
Table 10- 38 Description of the individual signals in Gn_ZSW
Bit
Name
0
"Find
Status:
reference
Function 1 - 4
1
mark" or
active
2
"Flying
3
measurement
"
4
Status:
Value 1 - 4
5
available
6
7
8
Probe 1
deflected
9
Probe 2 deflected
10
Reserved
11
Encoder fault acknowledge
active
12
Reserved
13
Transmit absolute value
cyclically
558
Signal status, description
Valid for "Find reference mark" and "Flying measurement"
Bit
Meaning
0
Function 1
1
Function 2
2
Function 3
3
Function 4
Note:
Bit x = 1 function active
Bit x = 0 function inactive
Valid for "Find reference mark" and "Flying measurement"
Bit
Meaning
4
Value 1
5
Value 2
6
Value 3
7
Value 4
Note:
Bit x = 1 value available
Bit x = 0 value not available
Only one value can be fetched at a time.
Reason: There is only one common status word Gn_XIST2 to read the values.
The probe must be configured to a "high-speed input" of the Control Unit.
1
Probe deflected (high signal)
0
Probe not deflected (low signal)
1
Probe deflected (high signal)
0
Probe not deflected (low signal)
-
1
Encoder fault acknowledge active
Note:
See under STW.15 (acknowledge encoder error)
0
No acknowledgement active
-
1
Acknowledgement for Gn_STW.13 (request absolute value cyclically)
Note:
Cyclic transmission of the absolute value can be interrupted by a function
with higher priority.
See Gn_XIST2
0
No acknowledgement
Reference mark 1
Probe 1 rising edge
Reference mark 2
Probe 1 falling edge
Reference mark 3
Probe 2 rising edge
Reference mark 4
Probe 2 falling edge
Reference mark 1
Probe 1 rising edge
Probe 1 falling edge
Probe 2 rising edge
Probe 2 falling edge
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents