Function diagrams (see SINAMICS S120/S150 List Manual)
● 9104 Analog inputs (AI 0 and AI 1)
● 9566 Analog input 0 (AI 0)
● 9568 Analog input 1 (AI 1)
● 9663 Analog input (AI 0)
CU310-2:
● 2040 Analog input (AI 0)
Parameter
● r0752[0] CO: CU analog input input voltage
● p0753[0] CU analog input smoothing time constant
● p0761[0] CU analog input wire breakage monitoring response threshold
● p0762[0] CU analog input wire breakage monitoring delay time
● CU analog input offset
● CU analog input activate absolute value generation
● BI: CU analog input enable signal source
CU310-2:
● r0755[0] CO: CU analog input actual value in percent
● p0756[0] CU analog input type
● p0757[0] CU analog input characteristic value x1
● p0758[0] CU analog input characteristic value y1
● p0759[0] CU analog input characteristic value x2
● p0760[0] CU analog input characteristic value y2
12.5.4

Analog outputs

Signal processing using the analog outputs is shown in the function diagrams listed below.
Properties
● Adjustable absolute-value generation
● Inversion via binector input
● Adjustable smoothing
● Adjustable transfer characteristic
● Output signal can be displayed via visualization parameter
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Basic information about the drive system
12.5 Inputs/outputs