● p0844 BI: 1. OFF2
● r0898 CO/BO: Control word sequence control infeed
● r0899 CO/BO: Status word sequence control infeed
● p1240[0...n] Vdc controller or Vdc monitoring configuration
● p1280[0...n] Vdc controller or Vdc monitoring configuration (U/f)
● r2138 CO/BO: Control word, faults/alarms
● r2139 CO/BO: Status word, faults/alarms 1
● p3680 BI: Inhibit Braking Module internally
1.3.2

Basic Infeed open-loop control

Description
The Basic Line Module can be controlled via a BICO interconnection, e.g. using terminals or
fieldbus. The operating status is indicated on the operating display r0002. The missing
enable signals for operation (r0002 = 00) are mapped in parameter r0046. The EP terminals
(enable pulses) must be connected in accordance with the Manual of the corresponding
power units.
Acknowledging faults
Faults that are still present but the causes of which have been rectified can be
acknowledged using a 0/1 edge at the "1. Acknowledge faults" signal (p2103).
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Infeed
1.3 Basic Infeed