Siemens Sinamics S120 Function Manual page 545

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

ITIST_GLATT
The current actual value smoothed with p0045 is displayed.
MIST
Actual torque value.
MIST_GLATT
The actual torque value smoothed with p0045 is displayed.
PIST_GLATT
The active power smoothed with p0045 is displayed.
NIST_A_GLATT
The speed actual value smoothed with p0045 is displayed.
MSOLL_GLATT
The torque setpoint smoothed with p0045 is displayed.
AIST_GLATT
Torque utilization smoothed with p0045 is displayed.
MELDW (message word)
See function diagram [2456]
Table 10- 29 Description of MELDW (message word)
Bit
Meaning
0
Ramp-up/ramp-down
completed/ramp-function generator
active
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Remarks
1
Ramp-up/ramp-down completed.
The ramp-up procedure is completed once the
speed setpoint has been changed.
1/0
Ramp-up starts.
The start of the ramp-up procedure is detected as
follows:
The speed setpoint changes,
and
The defined tolerance bandwidth (p2164) is
exited.
10.1 Communication according to PROFIdrive
Communication
Parameter
BO: r2199.5
543