2.8

Suppression bandwidths and setpoint limits

Description
In the range 0 U/min to setpoint speed, a drive train (e.g. motor, coupling, shaft, machine)
can have one or more points of resonance, which can result in vibrations. The suppression
bandwidths can be used to prevent operation in the resonance frequency range.
The limit frequencies can be set via p1080[D] and p1082[D]. Further, using connectors
p1085[C] and p1088[C] it is possible to influence these limits in operation.
Figure 2-10
Skip frequency bands, setpoint limitation, minimum speed
Minimum speed
Using parameter p1106[0...n], a minimum speed n_min s_src or minimum velocity can be
set, which is wired via BICO.
Drive functions
Function Manual, (FH1), 01/2012, 6SL3097-4AB00-0BP2
Extended setpoint channel
2.8 Suppression bandwidths and setpoint limits