Overview Of Safety Integrated Functions; Safety Integrated Basic Functions - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Overview of Safety Integrated functions

3.1

Safety Integrated Basic Functions

Not e
B as ic functions do not require an encoder
The Safety Integrated Basic Functions are functions for safely stopping the drive. You do not
require an encoder.
Not e
A pplication of t he B asic Functions
The Basic Functions are available without any restrictions in all control modes, with and
without an encoder, for synchronous, induction, and reluctance motors.
Not e
Cont rol via TM54F
If you want to control the Safety Integrated Basic Functions via TM54F, set p9601.6 = 1.
This chapter should provide first users with a quick overview of the principle mode of
operation of safety functions.
The entry into the description of the safety functions is based on the definition according to
standard EN 61800-5-2 and some simple examples for using the function.
The description of the functions is simplified, as far as possible to clearly shown essential
properties and setting options.
More information about the functions can be found in the following sections,
e.g.: "Safety Integrated basic functions (Page 62)".
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
3