● Change the password using STARTER
– Click the "Change password" button on the start screen of the configuration.
– In the subsequent dialog, first enter the old password.
– Enter the new password.
– Confirm the new password by entering it again.
– Click "OK" to accept the setting.
● Reset the password with STARTER
– Click the "Change password" button on the start screen of the configuration.
– In the subsequent dialog, first enter the old password.
– Set the new password = 0.
– Select the "Change settings" button.
– SINAMICS S120 responds with the message "Please change the password!"
– Close the message.
– In the "Change password" dialog box, then click the "Cancel" button.
– The password has now been reset to the default "0."
● If the safety password is no longer available, you can no longer change the safety
configuration. You then have the following options:
– To commission the SINAMICS S120 completely as new:
– To load another project into the drive (without a Safety password or with a known
– If neither option is acceptable to you, please contact "Technical Support" (see
Function diagrams (see SINAMICS S120/S150 List M anual)
• 2818
Ov erview of important parameters (see SINAMICS S120/S150 List Manual)
• p9761
• p9762
• p9763
• p10061
• p10062
• p10063
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
- Restore the factory settings of the entire drive (Control Unit with all connected
drives/components).
- Commission the drive unit and the drives afresh.
- Commission Safety Integrated as new.
Safety password). This is possible without a password because this operation is the
same as complete new commissioning.
"Preface (Page 5)").
SI Extended Functions - Parameter managers
SI password input
SI password new
SI password acknowledgment
SI TM54F password entry
SI TM54F password new
SI TM54F password confirmation
Commissioning
6.3 Handling the Safety password
223