S witching t o a lower speed level
Wi th braking ramp monitoring
(o nly without encoder)
•
•
The automatic reduction of the speed only takes effect when the ramp-function generator is inter-
1)
connected to the speed setpoint limitation.
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Once the "delay time for braking ramp" has
elapsed, the converter monitors the motor ve-
locity using the function SBR (Safe Brake
Ramp).
The converter switches over from SBR moni-
toring to level 2 of SLS monitoring as soon as
one of the following conditions is fulfilled:
–
The SBR monitoring ramp has reached
the value of the SLS monitoring.
This case is shown in the diagram above.
–
The load velocity has decreased down to
the value SLS monitoring and the "delay
time for braking ramp" has expired.
Wi thout braking ramp monitoring
1)
(w ith or without encoder)
The converter monitors the velocity with the
•
lower SLS level after the "delay time for SLS
changeover" has expired (this is the same de-
lay time that applies after selecting the func-
tion SLS).
Overview of Safety Integrated functions
3.2 Safety Integrated Extended Functions
51