6.9.4

TM54F configuration

Configuration screen of TM54F for Safety Integrated
Image 6-16
Functions of this screen:
● Assigning drive objects (p10010)
Select a drive object to be assigned to a drive group.
● Drive groups (p10011)
Each configured safety drive can be assigned to a drive group using a drop-down list box.
The list box displays the drives and their names.
● Safety communication clock (p10000[0..5])
Display of the Safety communication clock with which the TM54F communicates with the
relevant drive. Using the "Accept clocks from drives" button, update the display of the
communication clocks.
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
6.9 Commissioning TM54F by means of STARTER/SCOUT
TM54F configuration
Commissioning
297