A.3 Acceptance tests (recommendations)
Parameterizing the SI functions v ia TM54F
Table A- 6
SI function
Wait time for test stop on DO
Monitoring time discrepancy
Forced checking procedure timer
Acknowledging internal event input
terminal
Input terminal
forced checking procedure
SLP retraction F-DI
Assignment of drive objects
Assignment of drive groups
Digital inputs debounce time
STO input terminal
SS1 input terminal
SS2 input terminal
SOS input terminal
PLC input terminal
SLS_Limit(1) input terminal
418
Parameters for control via the TM54F (excerpt)
Pa rameter
p10001
p10002
p10003
p10006
p10007
p10009
p10010[0]
p10010[1]
p10010[2]
p10010[3]
p10010[4]
p10010[5]
p10011[0]
p10011[1]
p10011[2]
p10011[3]
p10011[4]
p10011[5]
p10017
p10022[0]
p10022[1]
p10022[2]
p10022[3]
p10023[0]
p10023[1]
p10023[2]
p10023[3]
p10024[0]
p10024[1]
p10024[2]
p10024[3]
p10025[0]
p10025[1]
p10025[2]
p10025[3]
p10026[0]
p10026[1]
p10026[2]
p10026[3]
p10027[0]
p10027[1]
p10027[2]
p10027[3]
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Va lue
500.00 ms
12.00 ms
8.00 h
0
0
1
0
0
0
0
0
0
1
1
1
1
1
1
1.00 ms
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Safety Integrated