Commissioning
6.8 Commissioning CU310-2 using STARTER/SCOUT
6.8
Commissioning CU310-2 using STARTER/SCOUT
This description explains commissioning using control via onboard terminals as example.
The following preconditions must be met to configure Safety Integrated on the CU310-2:
● Concluded initial commissioning of all drives
● Connect the sensors to the F-DIs and an actuator to the F-DO (if used)
Conf iguration s equence
1. Configuring Safety functions of the CU310-2
2. Configuring inputs (if used)
3. Configuring outputs (if used)
4. Copy parameters to the 2nd drive object
5. Change the safety password
6. Activate the configuration by selecting "Activate settings"
7. Save the project in STARTER
8. Save the project in the drive by selecting "Copy RAM to ROM"
9. Execute POWER ON
10. Acceptance test
282
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Safety Integrated