Commissioning Tm54F By Means Of Starter/Scout; Basic Sequence Of Commissioning - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Commissioning

6.9 Commissioning TM54F by means of STARTER/SCOUT

6.9
Commissioning TM54F by means of STARTER/SCOUT
6.9.1

Basic sequence of commissioning

The following conditions must be met before you can configure the TM54F:
● Initial commissioning of all drives has been completed.
● F-DIs and F-DOs of the TM54F that are to be used must be wired.
Conf iguration s equence
1. Insert the TM54F
2. Configure the TM54F and generate the drive groups
3. Configure Safety functions of the drive groups
4. Configure inputs, configure outputs
5. Copy parameters to the 2nd drive object (TM54F_SL)
6. Changing the safety password
7. Activate the configuration by selecting "Activate settings"
8. Save the project in STARTER
9. Save the project in the drive by selecting "Copy RAM to ROM"
10. Execute POWER ON
11. Acceptance test
294