Acceptance Tests; A.3.3 Acceptance Tests - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Appendix
A.3 Acceptance tests (recommendations)
SI function
Selection of test mode for test stop
SI F-DI F-DO test stop configuration
SI module identification TM54F
Safety equipment
Protective door
Protective door
switch
Mode selector
switch
Emergency Stop
button
Forced dormant
error detection
(test stop)
A.3.3

Acceptance tests

Not e
Conditions f or t he acceptance test
As far as possible, the acceptance tests are to be carried out at the maximum possible
machine speed and acceleration rates to determine the maximum braking distances and
braking times that can be expected.
Not e
A c ceptance test for B asic and Extended Functions
If Basic Functions and Extended Functions are combined, the acceptance test for both types
must be carried out for the functions used.
Not e
Trac e recordings
The trace recordings for the Extended Functions aid evaluation of the more complex
functionality compared with the Basic Functions, for which trace recording is not required.
However, these are only a suggestion; where necessary, you can also use other recording
options (e.g. via HMI).
420
Pa rameter
p10047[0]
p10047[1]
p10047[2]
p10047[3]
p10048
p10070
The protective door is unlocked by means of single-channel request key
The protective door is equipped with a safety door switch. The safety door switch
returns the dual-channel signal "Door closed and locked". Changeover and selec-
tion of safety functions in accordance with the table shown above.
The "Production" and "Setup" modes are set by means of a mode selector switch.
The key switch features two contact levels. Changeover and selection of safety
functions in accordance with the table shown above.
The dual-channel Emergency Stop pushbuttons are connected in series. The
Emergency Stop signal activates SS1 for all drives. Then the external brakes and
STO are activated.
Activation by means of:
Machine power on
Unlocking the protective door
Va lue
2
2
2
2
1
0
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Safety Integrated

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents