Siemens Sinamics S120 Function Manual page 378

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Standards and regulations
10.2 Safety of machinery in Europe
hydraulics, pneumatics, electrics, electronics, programmable electronics), risk classification
and architecture.
Standard IEC 61800-5-2:2007 is applicable for variable-speed electric drives with integrated
safety functions. IEC 61800-5-2 defines requirements and gives recommendations for
designing and developing, integrating and validating safety-related applications regarding
their functional safety. IEC 61800-5-2 is applicable for adjustable speed electric power drive
systems, which are handled in other parts of IEC 61800 standards.
Systems for executing safety-related control
functions
A
Non-electrical (e.g. hydraulic, pneumatic)
B
Electromechanical (e.g. relay and/or basic
electronics)
C
Complex electronics (e.g. programmable elec-
tronics)
D
A standards combined with B standards
E
C standards combined with B standards
F
C standards combined with A standards
or
C standards combined with A standards and B
standards
"X" indicates that the point is covered by this standard.
Comment 1:
Designated architectures are described in Annex B of EN ISO 13849-1 and provide a simplified basis for the quantification.
Comment 2:
For complex electronics: Using designated architectures in compliance with EN ISO 13849-1 up to PL = d or every archi-
tecture in compliance with EN 62061.
Comment 3:
For non-electrical systems: Use components that comply with EN ISO 13849-1 as sub-systems.
378
EN ISO 13849-1
X
Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
Restricted to the designated
architectures (see comment 1)
and max. up to PL = e
Restricted to the designated
architectures (see comment 1)
and max. up to PL = d
X
See comment 2
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
EN 62061
Not covered
All architectures and max. up to
SIL 3
All architectures and max. up to
SIL 3
X
See comment 3
All architectures and max. up to
SIL 3
X
See comment 3
Safety Integrated