Mitsubishi Electric MELSEC-Q QD75M User Manual page 702

Positioning module
Table of Contents

Advertisement

15 TROUBLESHOOTING
Related buffer memory address
Axis 1
Axis 2
Axis 3
Motor type
30102
30202
30302
Motor capacity
30103
30203
30303
Motor rotation speed
30104
30204
30304
Regenerative brake option
30102
30202
30302
Check point
Axis 4
30402
30403
30404
Alarm (A.32) occurs if power is
switched on after disconnection
of the U, V, W phase power
cables.
30402
Set correctly ( Pr.103 to Pr.105 ).
Change servomotor.
Correct the U, V, W phase wiring of the servo
amplifier.
Change the servo amplifier.
Correct the U, V, W phase wiring of the servo
amplifier.
Take noise suppression measures.
• Change lead.
• Connect correctly.
Set correctly.
• Change lead.
• Connect correctly.
Change the servo amplifier.
• For wire breakage of built-in regenerative brake
resistor, change the servo amplifier.
• For wire breakage of regenerative brake option,
change regenerative brake option.
Add regenerative brake option or increase
capacity.
Review the power supply.
Connect correctly.
Change the SSCNET cable.
Take measures against noise.
Connect terminal connector.
Set correctly.
15 - 39
MELSEC-Q
Corrective action

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents