Mitsubishi Electric MELSEC-Q QD75M User Manual page 447

Positioning module
Table of Contents

Advertisement

9 MAJOR POSITIONING CONTROL
Positioning start
signal
[Y10,Y11,Y12,Y13]
BUSY signal
[XC,XD,XE,XF]
M code ON signal
[X4,X5,X6,X7](WITH mode)
Cd.7 M code OFF request
Start complete signal
[X10,X11,X12,X13]
Md.26 Axis operation status
Positioning operation
External speed-position
switching command
Cd. 23 Speed-position switching
control movement amount
change register
Positioning complete signal
[X14,X15,X16,X17]
M code ON signal (AFTER mode)
[X4,X5,X6,X7]
Cd.7 M code OFF request
OPR complete flag
Md.31 Status: b4
Fig. 9.14 Operation timing and processing time during speed-position switching control (INC mode)
Normal timing time
t1
1.1
The t1 timing time could be delayed by the operation state of other axes.
Operation timing and processing time during speed-position switching
control (INC mode)
t1
Standing by
In speed control
t4
t2
t3
0 to 3.5
0 to 3.5
5.5 to 7.9
t2
t3
In position control
Standing by
Speed
Position
control
control
Speed control carried out until speed-position switching
signal turns ON
Position control movement amount is from the input position of
the external speed-position switching signal
t6
t5
t2
t4
t5
0 to 3.5
9 - 86
MELSEC-Q
t7
Unit: ms
t6
t7
1.0
Follows parameters