9 MAJOR POSITIONING CONTROL
Setting item
Da.1 Operation pattern
Da.2 Control system
Da.3 Acceleration time No.
Deceleration time
Da.4
No.
Axis to be
Da.5
interpolated
Positioning address/
Da.6
movement amount
Da.7 Arc address
Da.8 Command speed
Da.9 Dwell time
M code
Da.10
Refer to Section 5.3 "List of positioning data" for information on the setting details.
Positioning data setting example
[Reference axis is designated as axis 1.]
The following table shows setting examples when "4-axis linear interpolation
control (INC linear 4)" is set in positioning data No. 1 of axis 1. (The required
values are also set in positioning data No. 1 of axis 2, axis 3 and axis 4.)
Axis 1
Axis 2
Axis
(reference
(interpolation
axis) setting
axis) setting
example
example
Positioning
complete
INC linear 4
1
0
4000.0 µ m
8000.0 µ m
6000.00
mm/min
500ms
10
POINTS
When the "reference axis speed" is set during 4-axis linear interpolation control,
set so the major axis side becomes the reference axis. If the minor axis side is set
as the reference axis, the major axis side speed may exceed the "
limit value".
Refer to Section 9.1.6 "Interpolation control" for the reference axis and
interpolation axis combinations.
Axis 3
(interpolation
(interpolation
axis) setting
axis) setting
example
example
4000.0 µ m
3000.0 µ m
9 - 43
MELSEC-Q
Axis 4
Setting details
Set "Positioning complete"
assuming the next positioning
data will not be executed.
Set incremental system 4-axis
linear interpolation control.
Designate the value set in
" Pr.25
Acceleration time 1"
as the acceleration time at
start.
Designate the value set in
" Pr.10
Deceleration time 0"
as the deceleration time at
deceleration.
Setting not required (setting
value will be ignored).
When axis 1 is used as a
reference axis, the interpolation
axes are axes 2, 3 and 4.
Set the movement amount.
(Assuming "mm" is set in
" Pr.1
Unit setting".)
Setting not required (setting
value will be ignored).
Set the speed during
movement.
Set the time the machine
dwells after the positioning stop
(pulse output stop) to the
output of the positioning
complete signal.
Set this when other sub
operation commands are
issued in combination with the
No. 1 positioning data.