5 DATA USED FOR POSITIONING CONTROL
Setting item
Cd.19
OPR request flag OFF
request
Cd.20
Manual pulse generator 1
pulse input magnification
Cd.21
Manual pulse generator
enable flag
Cd.22
New torque value
The PLC program can use this data item to forcibly turn the OPR request flag
from ON to OFF.
This data item determines the factor by which the number of pulses from the
manual pulse generator is magnified.
Value "0"
: read as "1".
Value "101" or less: read as "100".
This data item enables or disables operations using a manual pulse generator.
Md.35
When changing the "
specify a new torque limit stored value.
Set a value within the allowable range of the "
5 - 150
Setting details
Torque limit stored value", use this data item to
Pr.17
Torque limit setting value".