Mitsubishi Electric MELSEC-Q QD75M User Manual page 143

Positioning module
Table of Contents

Advertisement

5 DATA USED FOR POSITIONING CONTROL
Item
Pr.47
Creep speed
Pr.48
OPR retry
Setting value, setting range
Value set with peripheral device
The setting value range differs depending on the "
setting".
Here, the value within the [Table 1] range is set.
[Table 1] on right page
0 : Do not retry OPR with limit
switch
1 : Retry OPR with limit switch
Pr.47 Creep speed
Set the creep speed after near-point dog ON (the low speed just before stopping
after decelerating from the OPR speed).
The creep speed is set within the following range.
Pr.46
(
OPR speed )
V
Machine OPR
start
Near-point
dog signal
OFF
Zero signal
Value set with PLC program
Pr.1
0
1
Pr.47
(
Creep speed)
OPR speed
Pr.46
5 - 52
MELSEC-Q
Setting value buffer memory
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
Unit
76
1
77
0
78
Pr.47
ON
address
226
376
526
227
377
527
228
378
528
Creep speed