Data Required For High-Level Positioning Control - Mitsubishi Electric MELSEC-Q QD75M User Manual

Positioning module
Table of Contents

Advertisement

10 HIGH-LEVEL POSITIONING CONTROL

10.1.1 Data required for high-level positioning control

"High-level positioning control" is executed by setting the required items in the "block
start data" and "condition data", then starting that "block start data". Judgment about
whether execution is possible, etc., is carried out at execution using the "condition
data" designated in the "block start data".
"Block start data" can be set for each No. from 7000 to 7004 (called "block Nos."), and
up to 50 points can be set for each axis. (This data is controlled with Nos. called
"points" to distinguish it from the positioning data. For example, the 1st block start data
item is called the "1st point block start data" or "point No. 1 block start data".)
"Condition data" can be set for each No. from 7000 to 7004 (called "block Nos."), and
up to 10 data items can be set for each axis.
The " block start data" and "condition data" are set as 1 set for each block No.
The following table shows an outline of the " block start data" and "condition data"
stored in the QD75.
Setting item
Da.11
Shape
Da.12
Start data No.
Special start
Da.13
instruction
Da.14
Parameter
Setting item
Da.15
Condition target
Condition
Da.16
operator
Da.17
Address
Da.18
Parameter 1
Da.19
Parameter 2
Set whether to end the control after executing only the "block
start data" of the shape itself, or continue executing the "block
start data" set in the next point.
Set the "positioning data No." to be executed.
Set the method by which the positioning data set in Da.12
will be started.
Set the conditions by which the start will be executed
according to the commands set in Da.13 . (Designate the
"condition data No." and "No. of repetitions".)
Designate the "device", "buffer memory storage details", and
"positioning data No." elements for which the conditions are
set.
Set the judgment method carried out for the target set
in Da.15 .
Set the buffer memory address in which condition judgment is
carried out (only when the details set in Da.15 are "buffer
memory storage details").
Set the required conditions according to the details set in
Da.15 and Da.16 .
Set the required conditions according to the details set in
Da.15 and Da.16 .
10 - 3
MELSEC-Q
Setting details
Setting details

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents