11 MANUAL CONTROL

11.2.4 Creating start programs for JOG operation

Setting item
Inching movement
Cd.16
amount
JOG speed
Cd.17
Refer to Section 5.7 "List of control data" for details on the setting details.
Interface
signal
External
signal
A PLC program must be created to execute a JOG operation. Consider the "required
control data setting", "start conditions" and "start time chart" when creating the
program.
The following shows an example when a JOG operation is started for axis 1.
Cd.17
("
JOG speed" is set to "100.00mm/min" in the example shown.)
Required control data setting
The control data shown below must be set to execute a JOG operation. The
setting is carried out with the PLC program.
Setting
value
0
Set "0".
10000 Set a value equal to or below the "
JOG speed limit value".
Start conditions
The following conditions must be fulfilled when starting. The required conditions
must also be assembled in the PLC program, and the PLC program must be
configured so the operation will not start if the conditions are not fulfilled.
Signal name
PLC READY signal
QD75 READY signal
All axis servo ON
Synchronization flag
Axis stop signal
Start complete signal
BUSY signal
Error detection signal
M code ON signal
Stop signal
Upper limit (FLS)
Lower limit (RLS)
If the PLC CPU is set to the asynchronous mode in the synchronization setting, this must be
inserted in the program for interlocking. If it is set to the synchronous mode, it must not be
inserted in the program for interlocking because it is turned ON when the PLC CPU executes
calculation.
Setting details
Signal state
ON PLC CPU preparation completed
ON QD75 preparation completed
ON All axis servo ON
QD75 buffer memory
ON
The access is possible.
OFF Axis stop signal is OFF
OFF Start complete signal is OFF
OFF QD75 is not operating
OFF There is no error
OFF M code ON signal is OFF
OFF Stop signal is OFF
ON Within limit range
ON Within limit range
11 - 10
MELSEC-Q
Buffer memory address
Axis
Axis
1
2
1517 1617 1717 1817
1518
1618
Pr.31
1519
1619
Device
Axis
Axis
1
2
Y0
X0
Y1
X1
Y4
Y5
X10 X11 X12 X13
XC
XD
X8
X9
X4
X5
Axis
Axis
3
4
1718
1818
1719
1819
Axis
Axis
3
4
Y6
Y7
XE
XF
XA
XB
X6
X7