5 DATA USED FOR POSITIONING CONTROL
Storage item
Md.106
Servo amplifier Software No.
Parameter error No.
Md.107
Md.108
Servo status
Regenerative load ratio
Md.109
Effective load torque
Md.110
Md.111
Peak torque ratio
This area stores the Software No. of the servo amplifier used.
When a servo parameter error occurs, the
bit that corresponds to the parameter
number affected by the error comes ON.
This area stores the servo status.
READY ON
Indicates the ready ON/OFF.
Servo ON
Indicates the servo ON/OFF.
Zero point pass
Turns ON if the zero point of the encoder has been passed even once.
In-position
The dwell pulse turns ON within the servo parameter "in-position."
Zero speed
Turns ON when the motor speed is lower than the servo parameter "zero speed."
Torque limit
Turns ON when the servo amplifier is having the torque restricted.
Servo alarm
Turn ON during the servo alarm.
Servo warning
Turn ON during the servo warning.
The rate of regenerative power to the allowable regenerative power is indicated
as a percentage.
When the regenerative option is used, the rate to the allowable regenerative
power of the option is indicated.
(Buffer memory) %
Update timing: 1 s
The continuous effective load torque is indicated.
The average value of the load rates for the past 15 seconds to the rated torque is
stored as a percentage, rated torque being 100%.
(Buffer memory) %
Update timing: 1s
The maximum torque is indicated. (Holding value)
The peak values for the past 15 seconds are indicated, rated torque being 100%.
(Buffer memory) %
Update timing: 1s
5 - 136
Storage details
Parameter error (No.1 to 15)
Parameter error (No.16 to 31)
Parameter error (No.32 to 47)
Parameter error (No.48 to 63)
Parameter error (No.64 to 75)
Not used
Not used
MELSEC-Q