Mitsubishi Electric MELSEC-Q QD75M User Manual page 684

Positioning module
Table of Contents

Advertisement

15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Refer to Section 5.4
"Block start data"
Refer to Section 5.3
"List of positioning data"
1504 1604 1704 1804
1500 1600 1700 1800
Refer to Section 5.3
"List of positioning data"
Set range
(Setting with PLC program)
<Special start instruction>
00
to 06
H
H
<M code OFF request>
1: M code ON signal is turned OFF
<Positioning start No.>
1 to 600,
7000 to 7004,
9001 to 9004
<Maximum radius>
536870912
<LOOP to LEND>
1 to 65535
Normalize the block start data.
Correct the instruction code of the special start data.
(Refer to Section 5.4
Correct the control system.
(Refer to Section 5.3
After turning OFF the M code ON signal, start the
system. (Refer to Section 12.7.3)
Check the PLC program which turns ON/OFF the PLC
READY signal (Y0), and turn ON the PLC READY
signal. Then start the system.
Check the QD75 READY ON signal, and then start the
system. (Refer to Section 3.3.2)
Review the positioning start No. to correct value.
(Refer to Section 12.7.8)
Correct the positioning data.
(Refer to Section 9.2.10, 9.2.11)
Set 1 to 65535 in LOOP. (Refer to Section 9.2.22)
15 - 21
MELSEC-Q
Remedy
Da.13
)
)
Da.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents