5 DATA USED FOR POSITIONING CONTROL
Pr.1
WITH mode......... An M code is output and the M code ON
signal is turned ON when a positioning
operation starts.
Positioning start signal
[Y10,Y11,Y12,Y13]
BUSY signal
[XC,XD,XE,XF]
M code ON signal
[X4,X5,X6,X7]
M code OFF request
Cd.7
[1504,1604,1704,1804]
Valid M code
Md.25
Positioning
Operation pattern
Da.1
: m1 and m2 indicate set M codes.
Note: If AFTER mode is used with speed control, an M code will not be output and the M code ON signal will not be
turned ON.
Pr.17 Torque limit setting value
Set the maximum value of the torque generated by the servomotor as a
percentage between 1 and 500%.
The torque limit function limits the torque generated by the servomotor within
the set range.
If the torque required for control exceeds the torque limit value, it is controlled
with the set torque limit value.
(Refer to "12.4.2 Torque limit function ".)
[Table 1]
Value set with peripheral device
setting value
0 : mm
0.1 to 214748364.7 (µm)
1 : inch
0.00001 to 21474.83647 (inch)
2 : degree
0.00001 to 21474.83647 (degree)
3 : PLS
1 to 2147483647 (PLS)
Pr.18 M code ON signal output timing
This parameter sets the M code ON signal output timing.
Choose either WITH mode or AFTER mode as the M code ON signal output
timing.
m1
m2
01 (continuous)
00 (end)
An M code is a number between 0 and 65535 that can be assigned to each positioning
Da.10
data (
).
The sequence program can be coded to read an M code from the buffer memory
address specified by "
X6, X7] turns ON so that a command for the sub work (e.g. clamping, drilling, tool
change) associated with the M code can be issued.
(unit)
AFTER mode ...... An M code is output and the M code ON
Positioning complete signal
[X14,X15,X16,X17]
BUSY signal
[XC,XD,XE,XF]
M code ON signal
[X4,X5,X6,X7]
Cd.7
M code OFF request
[1504,1604,1704,1804]
Valid M code
Md.25
Positioning
Operation pattern
Da.1
Md.25
Valid M code" whenever the M code ON signal [X4, X5,
5 - 31
MELSEC-Q
Value set with PLC program (unit)
1 to 2147483647 (×10
1 to 2147483647 (×10
1 to 2147483647 (×10
1 to 2147483647 (PLS)
signal is turned ON when a positioning
operation completes.
m1
01 (continuous)
: m1 and m2 indicate set M codes.
–1
µm)
–5
inch)
–5
degree)
m2
00 (end)