11 MANUAL CONTROL

11.4.3 Setting the required parameters for manual pulse generator operation

Pr.1
Unit setting
Pr.2
No. of pulses per rotation (AP) (Unit: PLS)
Pr.3
Movement amount per rotation (AL) (Unit: PLS)
Pr.4
Unit magnification (AM)
Pr.8
Speed limit value (Unit: PLS/s)
Pr.11
Backlash compensation amount (Unit: PLS)
Pr.12
Software stroke limit upper limit value (Unit: PLS)
Pr.13
Software stroke limit lower limit value (Unit: PLS)
Pr.14
Software stroke limit selection
Pr.15
Software stroke limit valid/invalid setting
Pr.17
Torque limit setting value (Unit: %)
Pr.22
Input signal logic selection
Pr.24
Manual pulse generator input selection
: Setting always required.
: Set according to requirements (Leave set to the initial value when not used.)
The "Positioning parameters" must be set to carry out manual pulse generator
operation.
The following table shows the setting items of the required parameters for carrying out
manual pulse generator operation. When only manual pulse generator operation will
be carried out, no parameters other than those shown below need to be set. (Use the
initial values or setting values within a range where no error occurs for trouble-free
operation.)
Setting item
REMARK
Positioning parameter settings work in common for all control using the QD75.
When carrying out other control ("major positioning control", "high-level positioning
control", "OPR positioning control"), the respective setting items must also be
matched and set.
Parameters are set for each axis. But
Pr.24
(b8),
is set only for axis 1. (The setting for axes 2,3, and 4 is ignored.)
Refer to Chapter 5 "Data Used for Positioning Control" for setting details.
Setting requirement
Pr.22
11 - 32
MELSEC-Q
Factory-set initial value
(setting details)
3 (PLS)
20000
20000
1 (1 times)
200000
0
2147483647
–2147483648
0 (current feed value)
0 (valid)
300
0 (Manual pulse generator
input is negative logic.)
0 (4 times multiplication of A
phase/B phase)
Manual pulse generator input logic