1 PRODUCT OUTLINE
Address(+)
direction
Address(-)
direction
Positininig start signal
Positioning start
complete signal
BUSY signal
Positioning complete
signal
(2) Continuous positioning control (operation pattern = 01: positioning
continues)
The operation stops temporarily upon the completion of positioning for the
specified positioning data, and then continues with the next positioning data
number.
This is specified when performing positioning in which the direction changes
because of multiple positioning data items having consecutive positioning data
numbers.
V
Positioning continues (01)
V
ON
OFF
ON
OFF
ON
OFF
OFF
Positioning continues (01)
ON
1 - 14
MELSEC-Q
Dwell time
t
Positioning
complete
(00)