SINAMICS parameters

7.2 SINAMICS V60 parameters

Par. No.
Name
p1821[0...n]
Direction of rotation
Description:
Setting to change the direction of rotation. If the parameter is changed, it reverses the direction of rotation of
the motor and the encoder actual value without changing the setpoint.
Dependency: F07434
Caution:
Changing the direction using p1820 or p1821 is not recognized by the "Safe Direction without encoder". As
a consequence, the limit provided by SDI (Safe Direction) from r9733 no longer functions.
Notice:
An appropriate fault is output for a drive data set changeover where the direction of rotation changes and the
pulses are enabled.
Note:
For operation with the phase sequence U/V/W, the direction of rotation is defined when viewing the face side
of the motor output shaft.
When changing the direction of rotation, the rotating field direction of the current controller is reversed. The
speed actual value (e.g. r0063) is also reversed so that the control sense is kept and internally causing the
direction of rotation to be reversed with the same setpoint. Further, the position actual values of the actual
encoder are reversed (e.g. r0482[0...2]).
p29000
Motor ID
Description:
Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value, ranging from 18
to 39. For a motor with an absolute encoder, the drive automatically reads the parameter value, ranging from
10009 to 10048.
Dependency: -
r3998[0...n]
First drive commissioning
Description:
Displays whether the drive still has to be commissioned for the first time.
0 = Yes
2 = No
Dependency: -
7.2
SINAMICS V60 parameters
Editable parameters
Par. No.
Name
P01
Parameter write protection
0: Sets all parameters other than P01 as read-only parameters.
1: Sets all parameters to be both readable and writable.
P01 automatically resets to 0 after power-on.
520
Min
Max
0
1
0
54251
0
65535
Range
Default
0 - 1
0
Factory
Unit
Data type
setting
[0] 0
-
I16
[0] 0
-
U16
-
-
U16
Increment
Unit
1
-
Effective
Can be
changed
IM
-
IM
T
IM
-
Effective
Immediately