Prog_Sd_Poweron_Init_Tab - Siemens SINUMERIK 808D Parameter Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Machine data
3.2 General machine data
Bit 3 == 1
Bit 4 == 1
channel mode.
Bit 5..31
Program test with normal processing is always activated via the VDI interface.
Program test in simulation is always activated via the NCKMode PI.
Program test block search is always activated via the Find-Pi.
10709

PROG_SD_POWERON_INIT_TAB

-
Setting data to be initialized
-
-
30
Description:
Setting data to be initialized:
The values of the programmable SD indicated in this MD are set to their initial values
on control power up.
Only the setting data listed in the table below, however, can be initialized. If
invalid setting data numbers are configured, then the alarm 4009 is output at the next
run-up of the control. The alarm shows the index used for configuring the invalid
setting data. The alarm can only be eliminated by changing the invalid setting data,
i.e. by entering either a valid number or zero!
SD42000 $SC_THREAD_START_ANGLE
SD42010 $SC_THREAD_RAMP_DISP
SD42125 $SC_SERUPRO_SYNC_MASK
SD42400 $SC_PUNCH_DWELLTIME
SD42402 $SC_NIBPUNCH_PRE_START_TIME
SD42404 $SC_MINTIME_BETWEEN_STROKES
SD42800 $SC_SPIND_ASSIGN_TAB
SD43200 $SA_SPIND_S
SD43202 $SA_SPIND_CONSTCUT_S
SD43210 $SA_SPIND_MIN_VELO_G25
SD43220 $SA_SPIND_MAX_VELO_G26
SD43230 $SA_SPIND_MAX_VELO_LIMS
SD43235 $SA_SPIND_USER_VELO_LIMIT
SD43300 $SA_ASSIGN_FEED_PER_REV_SOURCE
SD43350 $SA_AA_OFF_LIMIT
SD43420 $SA_WORKAREA_LIMIT_PLUS
SD43430 $SA_WORKAREA_LIMIT_MINUS
SD43600 $SA_IPOBRAKE_BLOCK_EXCHANGE
SD43610 $SA_ADISPOSA_VALUE
SD43700 $SA_OSCILL_REVERSE_POS1
SD43710 $SA_OSCILL_REVERSE_POS2
SD43720 $SA_OSCILL_DWELL_TIME1
SD43730 $SA_OSCILL_DWELL_TIME2
SD43740 $SA_OSCILL_VELO
SD43750 $SA_OSCILL_NUM_SPARK_CYCLES
SD43760 $SA_OSCILL_END_POS
SD43770 $SA_OSCILL_CTRL_MASK
SD43780 $SA_OSCILL_IS_ACTIVE
44
Activation of program test with accelerated feed in the simulation.
Activation of accelerated program test takes place in synchronized multi-
As yet unused.
43200, 43202, 0, 0, 0,
-
0, 0, 0...
EXP, N01
K1
DWORD
PowerOn
-
2/2
(GCODE)
SF
DITS/DITE
PDELAYON
SETMS
S wih G94,G95,G97,G971,G972
S with G96,G961,G962
G25 S
G26 S
LIMS
FPRAON
G26
G25
OSP1
OSP2
OST1
OST2
FA
OSNSC
OSE
OSCTRL
OS
M
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents