Siemens SINUMERIK 808D Parameter Manual page 283

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

35030
SPIND_DEFAULT_ACT_MASK
-
Time at which initial spindle setting is effective
CTEQ
-
-
Description:
SPIND_DEFAULT_ACT_MASK specifies the time at which the operating mode defined in
MD35020 $MA_SPIND_DEFAULT_MODE becomes effective. The initial spindle setting can be
assigned the following values at the following points in time:
0
1
2
Special cases:
If MD35040 $MA_SPIND_ACTIVE_AFTER_RESET = 1, the following supplementary conditions
are applicable:
SPIND_DEFAULT_ACT_MASK should be set to 0
If this is not possible, the spindle must be at a standstill prior to activation.
Related to:
MD35020 $MA_SPIND_DEFAULT_MODE (initial spindle setting)
MD35040 $MA_SPIND_ACTIVE_AFTER_RESET (spindle active after reset)
35032
SPIND_FUNC_RESET_MODE
-
Reset response of individual spindle functions
CTEQ
-
-
Description:
This data allows the "GWPS in every operating mode" function to be selected/deselected.
SPIND_FUNC_RESET_MODE, bit 0 = 0 : "GWPS in every operating mode" is deselected
SPIND_FUNC_RESET_MODE, bit 0 = 1 : "GWPS in every operating mode" is selected
35035
SPIND_FUNCTION_MASK
-
Spindle functions
CTEQ
-
-
Description:
This MD allows spindle-specific functions to be set.
The MD is bit-coded, the following bits are assigned:
Bit 0 = 1: Gear stage changes are suppressed with activated DryRun function for
Bit 1 = 1: Gear stage changes are suppressed with activated program test function
Bit 2 = 1: Gear stage change for programmed gear stage will finally be carried
Bit 3: reserved
Bit 4 = 1:
The programmed speed is transferred to SD 43200 $SA_SPIND_S (incl. speed default
settings via FC18 and synchronized actions).
S programmings that are not speed programmings are not written to the SD. These
include, for example, S value with constant cutting velocity (G96, G961), S value with
revolution-related dwell time (G4).
Bit 5 = 1:
Parameter Manual
List Manual, 01/2017
0x00
POWER ON
POWER ON and NC program start
POWER ON and RESET (M2/M30)
0x00
0x510
block programming (M40, M41 to M45), programming via FC18,
and synchronized actions.
for block programming (M40, M41 to M45), programming via
FC18, and synchronized actions.
out after deselection of DryRun or program test functions with REPOS.
A06, A10
BYTE
0
0x03
A06, A10
DWORD
0
0x01
A06, A10
DWORD
0
0x7FFFFFFF
Machine data
3.4 Axis-specific machine data
S1
Reset
2/2
M
-
PowerOn
1/1
M
K1, S1
Reset
1/1
M
283