Siemens SINUMERIK 808D Parameter Manual page 82

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Machine data
3.2 General machine data
808d-me62
14
808d-te42
14
808d-te62
14
808d-mte40
14
808d-mte60
14
Description:
For PROFIBUS/PROFINET only:
The trigger frequency is configured bit-by-bit
Bits
Bits 16-23: 0x01-0x14: process data number (a maximum of 20 words are permissible)
Bits 24-27:0x01: status change 0->1
Bits 28-31:0x10: send slot
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x0 Recording starts immediately
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x1 Recording starts on control power on
When MD13113 $MN_PROFIBUS_TRACE_START=1 and MD13114
$MN_PROFIBUS_TRACE_START_EVENT=0x2 Recording starts on loss of the sign of life
13120
CONTROL_UNIT_LOGIC_ADDRESS
-
Logical address of SINAMICS CU
-
808d-me42
1
808d-me62
5
808d-te42
1
808d-te62
5
808d-mte40
15
808d-mte60
15
Description:
For PROFIBUS/PROFINET, SINAMICS:
Logical I/O address of a SINAMICS-CU (Control Unit) on the PROFIBUS/PROFINET.
The cyclic DP communication with SINAMICS-CU is activated by taking over the
associated slot address from the STEP7 project. The onboard I/Os cannot be accessed
until after configuration.
13140
PROFIBUS_ALARM_ACCESS
-
Alarm response of PROFIBUS/PROFINET drives on power up
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
For PROFIBUS/PROFINET only:
Specifies the time of activation for evaluation/transmission of
PROFIBUS/PROFINET node alarms or warnings
(fine diagnostics messages) on the NCK.
Affects drive alarms or warnings 380500, 380501
82
0, 0, 0, 0, 0, 0, 0, 0...
0, 0, 0, 0, 0, 0, 0, 0...
0, 0, 0, 0, 0, 0, 0, 0...
0, 0, 0, 0, 0, 0, 0, 0...
0, 0, 0, 0, 0, 0, 0, 0...
0-15: 0x0001-0xffff: bit mask
0x00: status change 1->0
0x00: receive slot
6500, 0, 0, 0, 0, 0, 0, 0... 0
0
6500, 0, 0, 0, 0, 0, 0, 0... 0
0
6500, 0, 0, 0, 0, 0, 0, 0... 0
0
1
1
1
1
1
1
0x00000000
0x111fffff
0x00000000
0x111fffff
0x00000000
0x111fffff
0x00000000
0x111fffff
0x00000000
0x111fffff
N04, N10
DWORD
16383
0
8191
16383
0
8191
16383
0
8191
N04, N10
DWORD
0
2
0
2
0
2
0
2
0
2
0
2
1/1
M
0/0
S
1/1
M
2/2
M
2/2
M
-
PowerOn
ReadOnly
M
0/2
M
ReadOnly
M
0/2
M
7/2
M
0/2
M
-
Immediately
ReadOnly
M
ReadOnly
M
ReadOnly
M
ReadOnly
M
2/7
M
2/7
M
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced