Siemens SINUMERIK 808D Parameter Manual page 415

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Signal state 0
Application
Special cases,
errors, ...
Note for the
reader
DB3300
DBX1.7
Edge evaluation: No
Signal state 1
Signal state 0
Corresponding to ...
Note for the reader
Parameter Manual
List Manual, 01/2017
No end of program or program abort
Status after the control has been switched on
Start of an NC Program
The PLC can detect the end of program processing with this signal and react appro‐
priately.
● The M2 and M30 functions have equal priority. Only M2 should be used.
● The IS "M2/M30 active" is present as steady-state signal after the end of the
program.
● Not suitable for automatic follow-on functions such as workpiece counting, bar
feed, etc. For these functions, M2 should be written into a separate block and
the word M2 or the decoded M signal should be used.
● Auxiliary functions must not be written in the last block of a program that should
result in a read-in stop.
Function Manual Basic Functions K1
Program test active
Signal(s) from channel (NCK → PLC)
Signal(s) updated: Cyclic
Program control "Program test" is active. Axis disable is set internally for all
axes (not spindles). Therefore the machine axes do not move when a part
program block or a part program is being processed. The axis movements
are simulated on the operator interface with changing axis position values.
The axis position values for the display are generated from the calculated
setpoints.
Otherwise, the part program is executed in the normal way.
Program control program test is not active.
IS "Activate program test"
IS "Program test selected"
Function Manual Basic Functions K1
Detailed descriptions of interface signals
5.7 Channel-specific signals
415