Machine data
3.2 General machine data
MD20620 $MC_HANDWH_GEOAX_MAX_INCR_SIZE).
MD32080$MA_HANDWH_MAX_INCR_SIZE
The start of the traversing is taken as the zero point of the grid.
Value = 3:
The default settings of the handwheel are path inputs. If premature braking is
required on account of settings in other machine data
MD11310 $MN_HANDWH_REVERSE != 0
MD20624 $MC_HANDWH_CHAN_STOP_COND
MD32084 $MA_HANDWH_STOP_COND
then in contrast to value = 1 braking is not along the shortest possible path, but to
the next possible point in an intentional grid (see value = 2).
Value = 6:
Same as value = 2, but travel does not stop at the last possible grid position in front
of a limit, but at the limit.
Value = 7:
Same as value = 3, but travel does not stop at the last possible grid position in front
of a limit, but at the limit.
11350

HANDWHEEL_SEGMENT

-
Handwheel segment
-
808d-me42
6
808d-me62
6
808d-te42
6
808d-te62
6
808d-mte40
6
808d-mte60
6
Description:
Machine data defines which
hardware segment the handwheel is connected to:
0 = SEGMENT_EMPTY
1 = SEGMENT_840D_HW
2 = SEGMENT_8xxD_HW ;handwheel at 828D sl, 808D -HW
5 = SEGMENT_PROFIBUS
7 = SEGMENT_ETHERNET
11351

HANDWHEEL_MODULE

-
Handwheel module
-
808d-me42
6
808d-me62
6
808d-te42
6
808d-te62
6
808d-mte40
6
808d-mte60
6
Description:
Machine data specifies the hardware module to which
the handwheel is connected.
(Content dependent on MD11350 $MN_HANDWHEEL_SEGMENT):
0 = no handwheel configured
70
2, 2, 0, 0, 0, 0
2, 2, 0, 0, 0, 0
2, 2, 0, 0, 0, 0
2, 2, 0, 0, 0, 0
2, 2, 0, 0, 0, 0
2, 2, 0, 0, 0, 0
;no handwheel
;handwheel at 840D HW
;handwheel at PROFIBUS
;handwheel at Ethernet
1, 1, 0, 0, 0, 0
1, 1, 0, 0, 0, 0
1, 1, 0, 0, 0, 0
1, 1, 0, 0, 0, 0
1, 1, 0, 0, 0, 0
1, 1, 0, 0, 0, 0
MD11351 $MN_HANDWHEEL_MODUL =
N09
BYTE
0
-
0
-
0
-
0
-
0
-
0
-
N09
BYTE
0
6
0
6
0
6
0
6
0
6
0
6
H1
PowerOn
ReadOnly
M
ReadOnly
M
ReadOnly
M
ReadOnly
M
7/2
M
7/2
M
H1
PowerOn
ReadOnly
M
ReadOnly
M
ReadOnly
M
ReadOnly
M
7/2
M
7/2
M
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents