No.
Name
38000
MM_ENC_CO
MP_MAX_POI
NTS
Number of intermediate for interpolar compensation (SRAM)
* The machine data followed by an asterisk (*) have the access level of "Customer", while those without an asterisk have
the access level of "Manufacturer".
16.2

SINAMICS V70 parameters

This section lists only the parameters displayed on the drive BOP and those frequently used for drive commissioning. For
more parameters of the servo drive, see SINUMERIK 808D ADVANCED HMI through the following operations:
+
All parameters beginning with "p" are editable parameters, for example, p29000.
All parameters beginning with "r" are read-only parameters, for example, r0018.
Effective
Indicates the conditions for making parameterization effective. Two conditions are possible:
● IM (Immediately): Parameter value becomes effective immediately after changing.
● RE (Reset): Parameter value becomes effective after repower-on.
Can be changed
Indicates the state in which a parameter is changeable. Two states are possible:
● U (Run): Can be changed in the "Running" state when the enable signal is available. The "RDY" LED indicator lights up
green.
● T (Ready to run): Can be changed in the "Ready" state when the enable signal is missing. The "RDY" LED indicator
lights up red.
Note
When judging the state of the drive according to the "RDY" LED indicator, ensure that no faults or alarms exist.
Data type
Type
I16
I32
U16
U32
Uint16
Uint32
Float
Calling help information for V70 parameters
You can call the help information for the V70 drive parameters on the PPU by proceeding through the following steps:
+
Commissioning Manual
6FC5397-4EP10-0BA8, 07/2018
Default
Turning:
125
Milling: 200
1.
Select the system data operating area.
2.
Press this softkey to open the machine data window.
Range
Type
-
DWORD
Description
16-bit integer
32-bit integer
16 bits without sign
32 bits without sign
16-bit unsigned integer
32-bit unsigned integer
32-bit floating point number
Unit