Siemens SINUMERIK 808D Parameter Manual page 516

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

SINAMICS parameters
7.1 SINAMICS V70 parameters
Par. No.
Name
p1415
Speed setpoint filter 1 type
Description: Sets the type for speed setpoint filter 1.
● 0: Low pass: PT1
● 1: Low pass: PT2
● 2: General 2nd-order filter
Dependency:
● PT1 low pass: p1416
● PT2 low pass: p1417, p1418
● General filter: p1417 ... p1420
p1416
Speed setpoint filter 1 time
constant
Description: Sets the time constant for the speed setpoint filter 1 (PT1).
This parameter is only effective if the filter is set as a PT1 low pass.
Dependency: p1414, p1415
p1417
Speed setpoint filter 1 de‐
nominator natural frequency
Description: Sets the denominator natural frequency for speed setpoint filter 1 (PT2, general filter).
This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Dependency: p1414, p1415
p1418
Speed setpoint filter 1 de‐
nominator damping
Description: Sets the denominator damping for velocity setpoint filter 1 (PT2, general filter).
This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general filter.
Dependency: p1414, p1415
p1419
Speed setpoint filter 1 nu‐
merator natural frequency
Description: Sets the numerator natural frequency for speed setpoint filter 1 (general filter).
This parameter is only effective if the speed filter is set as a general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
Dependency: p1414, p1415
p1420
Speed setpoint filter 1 nu‐
merator damping
Description: Sets the numerator damping for speed setpoint filter 1 (general filter).
This parameter is only effective if the speed filter is set as a general filter.
Dependency: p1414, p1415
p1460
Speed controller P gain
adaptation speed, lower
Description: Sets the P gain of the speed controller before the adaptation speed range.
This value corresponds to the basic setting of the P gain of the speed controller without adaptation.
516
Min
Max
Factory
setting
0
2
0
0.00
5000.00
0.00
0.5
16000.0
1999.0
0.001
10.000
0.700
0.5
16000.0
1999.0
0.000
10.000
0.700
0.000
999999.0
0.300
00
Unit
Data type
Effective
-
I16
IM
ms
Float
IM
Hz
Float
IM
-
Float
IM
Hz
Float
IM
-
Float
IM
Nms/
Float
IM
rad