Mm_Num_Synact_Gud_Char; Mm_Num_Synact_Gud_String - Siemens SINUMERIK 808D Parameter Manual

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Machine data
3.2 General machine data
Field size corresponding to <value> of the relevant machine data
Predefined names:
SYG_AS[ ] -> Synact parameter of type AXIS in the SGUD block
SYG_AM[ ] -> Synact parameter of type AXIS in the MGUD block
SYG_AU[ ] -> Synact parameter of type AXIS in the UGUD block
SYG_A4[ ] -> Synact parameter of type AXIS in the GUD4 block
....
SYG_A9[ ] -> Synact parameter of type AXIS in the GUD9 block
The parameters can be read and written both by the part program and also via
synchronous actions.
18664

MM_NUM_SYNACT_GUD_CHAR

-
Configurable GUD variable of type Char
-
808d-me42
1
808d-me62
1
808d-te42
1
808d-te62
1
808d-mte40
9
808d-mte60
9
Description:
The MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[ ]
can be used to extend individual GUD blocks by additional
channel-specific parameter areas of type CHAR.
The GUD blocks are differentiated by the field index:
MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[0] =
MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[1] =
MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[2] =
MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[3] =
MD18664 $MN_MM_NUM_SYNACT_GUD_CHAR[8] =
In each case, fields with the following properties are created:
Data type CHAR
Field size corresponding to <value> of the relevant machine data
Predefined names:
SYG_CS[ ] -> Synact parameter of type CHAR in the SGUD block
SYG_CM[ ] -> Synact parameter of type CHAR in the MGUD block
SYG_CU[ ] -> Synact parameter of type CHAR in the UGUD block
SYG_C4[ ] -> Synact parameter of type CHAR in the GUD4 block
....
SYG_C9[ ] -> Synact parameter of type CHAR in the GUD9 block
The parameters can be read and written both by the part program
and also via synchronous actions.
18665

MM_NUM_SYNACT_GUD_STRING

-
Configurable GUD variable of type STRING
-
808d-me42
1
808d-me62
1
808d-te42
1
808d-te62
1
114
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
N02
-
DWORD
PowerOn
32767
0/0
32767
0/0
32767
0/0
32767
0/0
32767
7/2
32767
7/2
<value> -> extension of the SGUD block
<value> -> extension of the MGUD block
<value> -> extension of the UGUD block
<value> -> extension of the GUD4 block
<value> -> extension of the GUD9 block
N02
-
DWORD
PowerOn
25
0/0
25
0/0
25
0/0
25
0/0
S
S
S
S
M
M
S
S
S
S
Parameter Manual
List Manual, 01/2017

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik808d advanced

Table of Contents