SINAMICS parameters
7.1 SINAMICS V70 parameters
Par. No.
Name
p1120
Ramp-function generator
ramp-up time
Description: The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to
the maximum speed (p1082) in this time.
Dependency: p1082
p1121
Ramp-function generator
ramp-down time
Description: The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082)
down to standstill (setpoint = 0) in this time.
Further, the ramp-down time is always effective for OFF1.
Dependency: p1082
p1215
Motor holding brake config‐
uration
Description: Sets the holding brake configuration.
● 0: No motor holding brake being used
● 1: Motor holding brake according to sequence control
● 2: Motor holding brake always open
● 3: Motor holding brake like sequence control
Dependency: p1216, p1217, p1226, p1227, p1228
p1216
Motor holding brake, open‐
ing time
Description: Sets the time to open the motor holding brake.
After controlling the holding brake (opens), the speed/velocity setpoint remains at zero for this time. After
this, the speed/velocity setpoint is enabled.
This time should be set longer than the actual opening time of the brake, which ensures that the drive cannot
accelerate when the brake is applied.
Dependency: p1215, p1217
p1217
Motor holding brake closing
time
Description: Sets the time to apply the motor holding brake.
After OFF1 or OFF3 and the holding brake is controlled (the brake closes), then the drive remains closed-
loop controlled for this time stationary with a speed setpoint/velocity setpoint of zero. The pulses are sup‐
pressed when the time expires.
This time should be set longer than the actual closing time of the brake, which ensures that the pulses are
only suppressed after the brake has closed.
Dependency: p1215, p1216
514
Min
Max
Factory
setting
0.000
999999.0
10.000
00
0.000
999999.0
10.000
00
0
3
0
0
10000
100
0
10000
100
Unit
Data type
Effective
s
Float
IM
s
Float
IM
-
I16
IM
ms
Float
IM
ms
Float
IM
List Manual, 01/2017
Can be
changed
T, U
T, U
T
T, U
T, U
Parameter Manual