Siemens SINUMERIK 808D Parameter Manual page 107

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

The machine manufacturer's files are in this memory area of the passive file system.
E.g.: cycle programs
The settable values depend on the hardware and software configurations.
The settable size of the memory is, apart from the upper limit value,
determined by the MD18230 $MN_MM_USER_MEM_BUFFERED.
Index 0 = Minimum size of the battery-backed (persistent) part program / cycle program
memory
Index 1 = Reserved
Index 2 = Reserved
18354
MM_S_FILE_MEM_SIZE
-
Size of the Siemens cycle program memory
[0] Size of the volatile cycle program memory
[1] Size of the non-volatile Siemens cycle program memory
[2] Size of the volatile memory for system files (NRK fault file, etc.)
-
808d-me42
3
808d-me62
3
808d-te42
3
808d-te62
3
808d-mte40
3
808d-mte60
3
Description:
Memory for the control manufacturer's files in the passive file system ( in KB )
The control manufacturer's files are in this memory area of the passive file system,
e.g: cycle programs, system files
The settable values depend on the hardware and software configurations.
The settable size of the memory, apart from the upper limit value
for index = 0 is limited by the size of the available nonvolatile memory (see siehe
MD18230$MN_MM_USER_MEM_BUFFERED),
for index = 1, is limited by the size of the available non-volatile memory (see MD18210
$MN_MM_USER_MEM_DYNAMIC),
for Index = 2, is limited by the wize of the internally available buffered (SRAM)
memory.
Index 0 = Size of the nonvolatile cycle program memory
Index 1 = Size of the volatile Siemens cycle program memory; the data may be written,
but will overwritten during the runup by the value requested by the Siemens cycles.
Index 2 = Size of the non-volatile memory for system files in the SRAM. E.g. storage
location of the NRK fault file.
18355
MM_T_FILE_MEM_SIZE
-
Memory size for temporary files
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Memory for temporary files in the passive file system ( in KB ), e.g. compilations of
cycles (preprocessing), cycles on CF, system traces
Parameter Manual
List Manual, 01/2017
64, 0, 10
0
64, 0, 10
0
64, 0, 10
0
64, 0, 10
0
256, 0, 10
0
256, 0, 10
0
2048
0
2048
0
2048
0
2048
0
2048
0
2048
0
3.2 General machine data
EXP, N02
-
DWORD
PowerOn
256
0/0
256
0/0
256
0/0
256
0/0
512
7/2
512
7/2
EXP, N02
-
DWORD
PowerOn
1048576
0/0
1048576
0/0
1048576
0/0
1048576
0/0
1048576
7/2
1048576
7/2
Machine data
S
S
S
S
M
M
S
S
S
S
M
M
107