Machine data
3.3 Channel-specific machine data
20152
GCODE_RESET_MODE
-
Reset response of G groups
-
808d-me42
70
808d-me62
70
808d-te42
70
808d-te62
70
808d-mte40
70
808d-mte60
70
Description:
This MD is only evaluated if bit 0 is set in MD20110 $MC_RESET_MODE_MASK.
For each entry in MD20150 $MC_GCODE_RESET_VALUES (that is for each G group), this MD
is used to determine whether, on reset/part program end, the setting in MD20150
$MC_GCODE_RESET_VALUES is used again (MD = 0) or the current setting is retained (MD
= 1).
Example 1:
Here, the basic setting for the 6th G group (current plane) is read from MD20150
$MC_GCODE_RESET_VALUES at each reset / part program end:
MD20150 $MC_GCODE_RESET_VALUES[5]=1 ; reset value of the 6th G group is G17
MD20152$MC_GCODE_RESET_MODE[5]=0 ; after reset / part program end, the basic setting
for 6th G group corresponds to MD20150 $MC_GCODE_RESET_VALUES[5]
However, if the current setting for the 6th G group (current plane) is to be retained
after reset / part program end, then the following setting results:
MD20150 $MC_GCODE_RESET_VALUES[5]=1 ; reset value of the 6th G group is G17
MD20152 $MC_GCODE_RESET_MODE[5]=1 ; current setting for the 6th G group
;is retained even after reset / part program end.
Example 2:
Here, the basic setting for the 8th G group (work offset) is read from MD20150
$MC_GCODE_RESET_VALUES at each reset / part program end
MD20150 $MC_GCODE_RESET_VALUES[7]=2 ; Reset value of the 8th G group is G54
MD20152 $MC_GCODE_RESET_MODE[7]=0 after reset / part program end, the basic setting
for the 8th G group corresponds to MD20150 $MC_GCODE_RESET_VALUES[7]
If G54 was already active, especially at the time of reset, the values of the
corresponding data handling frame at the time of reset are activated.
However, if the current setting for the 8th G group (work offset) is to be retained
after reset / part program end, then the following setting results:
MD20152 $MC_GCODE_RESET_MODE[7]=1 ; if a work offset (e.g. G54) was active at the time
of reset, then the values of the corresponding data handling frame at the time of reset
are activated (that is UIFR[1] with G54)
Related to:
MD20110 $MC_RESET_MODE_MASK
MD20112 $MC_START_MODE_MASK
140
0, 0, 0, 0, 0, 0, 0, 1, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 1, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 1, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 1, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 0, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,, ...
0, 0, 0, 0, 0, 0, 0, 0, 0,
0
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,, ...
C03
M1, K1, K2, P1
BYTE
Reset
1
1/1
1
1/1
1
1/1
1
1/1
1
1/1
1
1/1
M
M
M
M
M
M