Siemens SINUMERIK 808D Parameter Manual page 392

Hide thumbs Also See for SINUMERIK 808D:
Table of Contents

Advertisement

Detailed descriptions of interface signals
5.6 Mode signals
DB3000
DBX0.2
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Signal irrelevant for ...
corresponding to ...
Note for the reader
DB3000
DBX0.4
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0
Note for the reader
DB3000
DBX0.7
Edge evaluation: Yes
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
corresponding to ...
Special cases, er‐
rors, ...
Note for the reader
DB3000
DBX1.2
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
392
JOG mode
Signal(s) to NCK (PLC → NCK)
Signal(s) updated: Cyclic
JOG mode is selected by the PLC program.
JOG mode is not selected by the PLC program.
if signal "Mode change disable"
IS "active JOG mode"
Function Manual Basic Functions K1
Mode change disable
Signal(s) to NCK (PLC → NCK)
Signal(s) updated: Cyclic
The currently active mode (JOG, MDI or Automatic) cannot be changed.
The mode can be changed.
Function Manual Basic Functions K1
Reset
Signal(s) to NCK (PLC → NCK)
Signal(s) updated: Cyclic
The channel should change into the "RESET" state. The program being exe‐
cuted is then in the program "Aborted" program state. All moving axes and
spindles are decelerated to zero speed according to their acceleration ramp
without contour violation. The initial settings are set (e.g. for G functions). The
alarms are cleared if they are not POWER ON alarms.
Channel status and program execution are not influenced by this signal.
IS "Channel reset"
IS "all channels in the Reset state"
An alarm that withdraws the IS "808D-Ready" ensures that the channel is no
longer in the Reset state. A "Reset" must be initiated in order to be able to
switch over to another mode.
Function Manual Basic Functions K1
Machine function REF
Signal(s) to NCK (PLC → NCK)
Signal(s) updated: Cyclic
Machine function REF is activated in the JOG mode.
Machine function REF is not activated.