Execution of the replacement subprogram at end of block (default value)
Bit 1 = 1
Execution of the replacement subprogram at block start
Bit 2 = 0:
Execution of the replacement subprogram according to the settin of bit 1
Bit 2 = 1:
Execution of the replacement subprogram at block start and at end of block.
10720

OPERATING_MODE_DEFAULT

-
Setting of mode after power ON
-
-
1
Description:
Default modes of the mode groups after power ON.
If no mode is selected by the PLC, all the channels associated with mode group n are
in the mode preset by OPERATING_MODE_DEFAULT[ n -1 ] after power ON:
0 = Automatic mode
1 = Automatic mode, submode REPOS
2 = MDI mode
3 = MDI mode, submode REPOS
5 = MDI mode, submode Reference point approach
6 = JOG mode
7 = JOG mode, submode Reference point approach
NOTICE! Depending on the machine data MD10721 $MN_OPERATING_MODE_EXTENDED, the mode
set here might not be adopted after power ON
10721

OPERATING_MODE_EXTENDED

-
Extended setting of mode after power ON
-
-
1
Description:
Extended setting of an operating mode of the operating mode groups after power on:
0 = Selection of the operating mode according to MD10720 $MN_OPERATING_MODE_DEFAULT
1 = Selection of the JOG mode if the PLC signal "Retract data available"
(DB3300.DBX4005.5) is set in at least one channel of the operating mode group
10722

AXCHANGE_MASK

-
Parameterization for axis replacement behavior
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
The axis replacement behavior can be changed with this
machine data.
Bit0 = 1
Means that there is an automatic axis replacement via channels even if the axis has
been brought into a neutral state by Waitp.
Bit1 = 1
Parameter Manual
List Manual, 01/2017
7, 7, 7, 7, 7, 7, 7, 7...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0
0
0
0
0
0
0
0
0
0
0
0
3.2 General machine data
N01
H2
BYTE
PowerOn
12
1/1
N01
H2
BYTE
PowerOn
1
1/1
EXP, N01
K5
DWORD
PowerOn
0xFFFF
0/0
0xFFFF
0/0
0xFFFF
0/0
0xFFFF
0/0
0xFFFF
7/2
0xFFFF
7/2
Machine data
M
M
S
S
S
S
M
M
49